Megalam ProSafe

HEPA (H14) and ULPA (U15, U16, U17) filter panels especially made for turbulent and laminar airflow applications in high-tech cleanrooms, clean benches and clean air devices. Optimized for LifeScience and Food&Beverage industry with glass fiber media for low pressure drop and long life time

  • Prosafe certified for Pharma, Food & Beverage
  • 100% filter scan tested according to ISO29463
  • Chemically resistant to decontamination and cleaning agent
  • Microbial inert components acc. to ISO 846
  • Tested for food safety acc. to EC 1935:2004
  • Hygienic product acc. to VDI 6022 and ISO846
  • Free of bisphenol-A, phthalate and formaldehyde
  • Manufactured and packed in a controlled environment
  • ICON9 en1822
  • ICON20 prosafe
  • ICON42 UL logo
Item Type Filter Class EN1822 Width (mm) Height (mm) Depth (mm) Airflow (m3/h) Pressure drop Initial (Pa)
MD13- 305x610-10/22 H13 305 610 66 301 116
MD13- 610x610-10/22 H13 610 610 66 603 115
MD13- 914x610-10/22 H13 915 610 66 903 114
MD13- 1219x610-10/22 H13 1220 610 66 1205 114
MD13- 610x610x76-11/22 H13 610 610 78 603 118
Megalam MD13LS-305x610x71-10/22 H13 305 610 71 301 116
Megalam MD13LS-610x610x71-10/22 H13 610 610 71 603 115
Megalam MD13LS-914x610x71-10/22 H13 914 610 71 903 114
Megalam MD13LS-1219x610x71-10/22 H13 1219 610 71 1205 114
Megalam MD14-305x610-10/22 H14 305 610 66 300 150
Megalam MD14-610x610-10/22 H14 610 610 66 600 140
Megalam MD14-914x610-10/22 H14 914 610 66 905 140
Megalam MD14-1219x610-10/22 H14 1219 610 66 1205 140
Megalam MX14-305x610-10/22 H14 305 610 90 300 105
Megalam MX14-610x610-10/22 H14 610 610 90 605 95
Megalam MX14-914x610-10/22 H14 914 610 90 905 95
Megalam MX14-1219x610-10/22 H14 1219 610 90 1205 95
Megalam MG14-305x610-10/22 H14 305 610 110 302 75
Megalam MG14-610x610-10/22 H14 610 610 110 605 65
Megalam MG14-914x610-10/22 H14 914 610 110 905 64
Megalam MG14-1219x610-10/22 H14 1219 610 110 1205 64
Megalam MD15-305x610-10/22 U15 305 610 66 300 160
Megalam MD15-610x610-10/22 U15 610 610 66 600 150
Megalam MD15-914x610-10/22 U15 914 610 66 903 145
Megalam MD15-1219x610-10/22 U15 1219 610 66 1205 145
Megalam MX15-305x610-10/22 U15 305 610 90 300 125
Megalam MX15-610x610-10/22 U15 610 610 90 605 115
Megalam MX15-914x610-10/22 U15 914 610 90 905 115
Megalam MX15-1219x610-10/22 U15 1219 610 90 1205 115
Megalam MG15-305x610-10/22 U15 305 610 110 301 90
Megalam MG15-610x610-10/22 U15 610 610 110 603 80
Megalam MG15-914x610-10/22 U15 914 610 110 905 80
Megalam MG15-1219x610-10/22 U15 1219 610 110 1205 80

Specifications

Application
Hepa/ULPA filter for clean rooms and LAF benches
Filter Frame
Extruded anodized aluminium
Media
Glass fiber
Max temperature (°C)
70 °C
Relative Humidity
100%
Recommended final pressure drop
2x Initial pressure drop
Separator
Hot-melt
Gasket
Silicone Gel, Seamless PU foamed gasket
Grille, Downstream
Expanded metal painted (RAL 9010)
Grille, Upstream
Expanded metal painted (RAL 9010)
Sealant
Polyurethane
Max Airflow
Nominal flow rate (if not, efficiency drops)
Max. final pressure drop
MD: 500 Pa, MX: 600 Pa, MG:800 Pa
Comment
All filter tested acc. to EN 1822 with individual protocol and packed in PE-film. Compliant with Prosafe requirements. Other editions on request.
Fire rating: UL 900

Related Products

Articles related to Megalam

Camfil trailer parked in front of nuclear power plant and cooling towers.

The mighty HEPA filter

ในขอบเขตของสภาพแวดล้อมที่มีการควบคุมความสะอาดที่เข้มงวด HEPA Filter เป็นส่วนหนึ่งที่สำคัญที่อาจถูกลืมเลือน

Life science and healthcare Sustainability Food and beverage Education and experience

มลพิษทางอากาศส่งผลต่อความเสี่ยงในการก่อเกิดโรคมะเร็ง การป้องกันและลดความเสี่ยงมลพิษทางอากาศ - การกรองอากาศ

ไม่น่าแปลกใจเลยที่มลพิษทางอากาศมีส่วนเกี่ยวข้องกับมะเร็งปอด อย่างไรก็ตามสิ่งที่น่าตกใจก็คืออากาศที่ไม่ดีสามารถเพิ่มความเสี่ยงต่อการเสียชีวิตจากมะเร็งชนิดอื่น ๆ ได้เช่นมะเร็งเต้านมตับและมะเร็งตับอ่อน

Air quality Air cleaners and air purifiers

กลยุทธ์การเปลี่ยนตัวกรอง

Gas Turbine Application: คุณภาพของตัวกรองอากาศเข้าเป็นสิ่งจำเป็นสำหรับประสิทธิภาพของกังหันก๊าซ การปกป้องกังหันด้วยโซลูชันการกรองเฉพาะไซต์จะช่วยเพิ่มผลกำไร

Energy and Power Systems