Megalam EnerGuard

Terminal Hepa filter panel for laminar and turbulent airflows with innovative robust polymeric filter media with lowest TCO thanks to long lifetime, low energy consumption and zero handling and installation damages.

  • Prosafe certified for Pharma, Food & Beverage industries
  • Durable media for 0% installation failure
  • Up to 50% energy savings compared to glass fibre filters
  • Free of bisphenol-A, phthalates and formaldehyde
  • Chemically resistant to decontamitation and cleaning agents
  • Long lifetime through depth loading media
  • Hygienic product acc. to VDI 6022 and ISO846
  • Tested for food safety acc. to EC 1935:2004
  • Manufactured and packed in a controlled environment
  • ICON9 en1822
  • ICON20 prosafe
Item Type Filter Class EN1822 Width (mm) Height (mm) Depth (mm) AirFlow (m3/h) @ 0,45m/s Pressure drop (Pa) @ 0,45 m/s
MD14/EG-G10-305x305x66-1PU/PS H14 305 305 66 151 105
MD14/EG-G10-305x610x66-1PU/PS H14 305 610 66 301 100
MD14/EG-G10-457x457x66-1PU/PS H14 457 457 66 338 100
MD14/EG-G10-457x610x66-1PU/PS H14 457 610 66 452 95
MD14/EG-G10-610x610x66-1PU/PS H14 610 610 66 603 90
MD14/EG-G10-762x610x66-1PU/PS H14 762 610 66 753 90
MD14/EG-G10-915x610x66-1PU/PS H14 915 610 66 904 90
MD14/EG-G10-1220x610x66-1PU/PS H14 1220 610 66 1206 90
/
MX14/EG-G10-305x305x90-1PU/PS H14 305 305 90 151 80
MX14/EG-G10-305x610x90-1PU/PS H14 305 610 90 301 75
MX14/EG-G10-457x457x90-1PU/PS H14 457 457 90 338 75
MX14/EG-G10-457x610x90-1PU/PS H14 457 610 90 452 70
MX14/EG-G10-610x610x90-1PU/PS H14 610 610 90 603 65
MX14/EG-G10-762x610x90-1PU/PS H14 762 610 90 753 65
MX14/EG-G10-915x610x90-1PU/PS H14 915 610 90 904 65
MX14/EG-G10-1220x610x90-1PU/PS H14 1220 610 90 1206 65

Video

Specifications

Application
For any application requiring terminal HEPA filtration including life science, food & beverage, hospitals.
Filter Frame
Extruded anodized aluminium
Media
Multi-fibre polymeric
Max temperature (°C)
70ºC
Relative Humidity
100%
Recommended final pressure drop
2x Initial pressure drop
Separator
Hot-melt
Gasket
Polyurethane, endless foamed
Grille, Downstream
Expanded metal painted (RAL 9010)
Sealant
Polyurethane
Max Airflow
30 000 m³/h
Max. final pressure drop
MD: 500 Pa, MX: 600 Pa
Comment
All filter tested acc. to EN 1822 with individual scan protocol and single packed in PE-film. Compliant with ProSafe** requirements
Other editions are available on request

Articles related to Megalam

Camfil trailer parked in front of nuclear power plant and cooling towers.

The mighty HEPA filter

In the realm of controlled environments, where precision, purity, and protection are paramount, High-Efficiency Particulate Air (HEPA) filters emerge as unsung heroes

Life science and healthcare Sustainability Food and beverage Education and experience

Air pollution and cancer mortality risks

It’s no surprise that air pollution has also been associated with lung cancer. What is shocking, however, is that bad air can also increase the risk of mortality from other types of sarcoma, including breast, liver, and pancreatic cancer.

Air quality Air cleaners and air purifiers

Filter replacement strategies

Gas Turbine Application: The quality of air inlet filters is essential for optimal gas turbine performance. Protecting the turbine with site-specific filtration solutions will assure profits are kept high.

Energy and Power Systems

Let Camfil be your clean air partner. Contact us today!
international contacts